STANDARD PRESSURE RANGES FOR TYPES: PBX, PBX-SF, PBB, PMS, PMX, PPB, PBS, PFS, PBQ, PFQ, PBR, PBT, RPX, PBX-SS |
PRESSURE RANGES
|
||||||||||||||
| ........................................................................................................... | case dimensions (in mm)
|
|||||||||||||
|
(IN MBAR)** |
scale division
|
|||||||||||||
cl. 1.6 |
option
cl. 1.0 |
Ø100 |
Ø160 |
Ø250 |
72x72 |
96x96 |
144x144 |
192x192 |
72x144 144x72 |
192x96 96x192 |
||||
| -4...0 | 0 ...4 |
0.1 |
0.1 |
x |
• |
x |
x |
x |
• |
• |
x |
• |
||
| -6...0 | 0 ...6 |
0.1 |
0.1 |
x |
• |
x |
x |
x |
• |
• |
• |
• |
||
| -10...0 | 0 ...10 |
0.2 |
0.2 |
x |
• |
• |
x |
x |
• |
• |
• |
• |
||
| -16...0 | 0 ...16 |
0.5 |
0.5 |
x |
• |
• |
x |
x |
• |
• |
• |
• |
||
| -25...0 | 0 ...25 |
0.5 |
0.5 |
• |
• |
• |
x |
q |
• |
• |
• |
• |
||
| -40...0 | 0 ...40 |
1 |
1 |
• |
• |
• |
• |
• |
• |
• |
• |
• |
||
| -60...0 | 0 ...60 |
1 |
1 |
• |
• |
• |
• |
• |
• |
• |
• |
• |
||
| -100...0 | 0 ...100 |
2 |
2 |
• |
• |
• |
• |
• |
• |
• |
• |
• |
||
| -160 ...0 | 0 ...160 |
5 |
5 |
• |
• |
• |
• |
• |
• |
• |
• |
• |
||
| -250 ...0 | 0 ...250 |
5 |
5 |
• |
• |
• |
• |
• |
• |
• |
• |
• |
||
| -400 ...0 | 0 ...400 |
10 |
10 |
• |
• |
• |
• |
• |
• |
• |
• |
• |
||
| -2.5 ...1.5 | -1.5 ...2.5 |
0.1 |
0.1 |
x |
• |
x |
x |
x |
• |
• |
x |
• |
||
| -4 ...2 | -2 ...4 |
0.1 |
0.1 |
x |
• |
x |
x |
x |
• |
• |
• |
• |
||
| -6 ...4 | -4 ...6 |
0.2 |
0.2 |
x |
• |
• |
x |
x |
• |
• |
• |
• |
||
| -10 ...6 | -6 ...10 |
0.5 |
0.5 |
x |
• |
• |
x |
x |
• |
• |
• |
• |
||
| -15 ...10 | -10 ...15 |
0.5 |
0.5 |
• |
• |
• |
x |
• |
• |
• |
• |
• |
||
| -25 ...15 | -15 ...25 |
1 |
1 |
• |
• |
• |
• |
• |
• |
• |
• |
• |
||
| -40 ...20 | -20 ...40 |
1 |
1 |
• |
• |
• |
• |
• |
• |
• |
• |
• |
||
| -60 ...40 | -40 ...60 |
2 |
2 |
• |
• |
• |
• |
• |
• |
• |
• |
• |
||
| -100 ...60 | -60 ...100 |
5 |
5 |
• |
• |
• |
• |
• |
• |
• |
• |
• |
||
| -150 ...100 | -100 ...150 |
5 |
5 |
• |
• |
• |
• |
• |
• |
• |
• |
• |
||
| -250 ...150 | -150 ...250 |
10 |
10 |
•
|
•
|
•
|
•
|
•
|
•
|
•
|
•
|
•
|
||
| 0 ...4000 upto 0 ...7000 see page 4a |
||||||||||||||
| NON STANDARD RANGES | ||||||||||||||
e.g. 0-50 bar |
||||||||||||||
DOUBLE SCALES |
||||||||||||||
e.g. mbar/mmWc, mbar/Pa, etc.
|
q |
|||||||||||||
ACCURACY |
||||||||||||||
±1.6% F.S. (class 1.6) |
• |
• |
• |
• |
• |
• |
• |
• |
• |
|||||
±1.0% F.S. (class 1.0)* |
q |
q |
q |
x |
q |
q |
q |
q |
q |
|||||
Mirrorscale |
x |
q |
q |
x |
x |
x |
x |
x |
x |
|||||
x |
NOT AVAILABLE |
* |
not for type PMS and PMX |
|||||||||||
• |
STANDARD
|
** |
Scale in psi,kPa, kg/cm², mWC etc. available with no extra charge
|
|||||||||||
MARKING FOR PRESSURE GAUGES |
|
| OPTIONS | EXTRA PRICE |
| TAG number on dial | |
| TAG number on AISI304/1.4301 TAG plate 55x25 mm | |
| Lettering on dial | |
| Red mark on dial | |
CERTIFICATES FOR PRESSURE GAUGES |
|||
| TYPE OF CERTIFICATE | EXTRA PRICE | ||
| Certificate of Conformity acc. to EN 10204 2.2. | |||
| Material certificate wetted parts acc. to EN 10204 3.1.B | |||
| Calibration certificate pressure gauge (Traceable to N.K.O.) | <=2500 |
2500 -4000 |
>=4000 |
| Red mark on dial | |||
| Calibration certificate pressure gauge with transmitter (see page 27) (Traceable to N.K.O.) | N.A. |
N.A. |
|
| Calibration certificates for type PBB (duplex) (Traceable to N.K.O.) | N.A. |
N.A. |
|