STANDARD PRESSURE RANGES FOR TYPES:
PBX, PBX-SF, PBB, PMS, PMX, PPB, PBS, PFS, PBQ, PFQ, PBR, PBT, RPX, PBX-SS |
|
PRESSURE RANGES
|
||||||||||||||
|
case dimensions
(in mm)
|
||||||||||||||
|
(IN MBAR)**
|
scale
division
|
|||||||||||||
|
cl. 1.6 |
option
cl. 1.0
|
Ø100
|
Ø160
|
Ø250
|
72x72
|
96x96
|
144x144
|
192x192
|
72x144
144x72 |
192x96
96x192 |
||||
| -4...0 |
0 ...4
|
0.1
|
0.1
|
x
|
•
|
x
|
x
|
x
|
•
|
•
|
x
|
•
|
||
| -6...0 |
0 ...6
|
0.1
|
0.1
|
x
|
•
|
x
|
x
|
x
|
•
|
•
|
•
|
•
|
||
| -10...0 |
0 ...10
|
0.2
|
0.2
|
x
|
•
|
•
|
x
|
x
|
•
|
•
|
•
|
•
|
||
| -16...0 |
0 ...16
|
0.5
|
0.5
|
x
|
•
|
•
|
x
|
x
|
•
|
•
|
•
|
•
|
||
| -25...0 |
0 ...25
|
0.5
|
0.5
|
•
|
•
|
•
|
x
|
q
|
•
|
•
|
•
|
•
|
||
| -40...0 |
0 ...40
|
1
|
1
|
•
|
•
|
•
|
•
|
•
|
•
|
•
|
•
|
•
|
||
| -60...0 |
0 ...60
|
1
|
1
|
•
|
•
|
•
|
•
|
•
|
•
|
•
|
•
|
•
|
||
| -100...0 |
0 ...100
|
2
|
2
|
•
|
•
|
•
|
•
|
•
|
•
|
•
|
•
|
•
|
||
| -160 ...0 |
0 ...160
|
5
|
5
|
•
|
•
|
•
|
•
|
•
|
•
|
•
|
•
|
•
|
||
| -250 ...0 |
0 ...250
|
5
|
5
|
•
|
•
|
•
|
•
|
•
|
•
|
•
|
•
|
•
|
||
| -400 ...0 |
0 ...400
|
10
|
10
|
•
|
•
|
•
|
•
|
•
|
•
|
•
|
•
|
•
|
||
| -2.5 ...1.5 |
-1.5 ...2.5
|
0.1
|
0.1
|
x
|
•
|
x
|
x
|
x
|
•
|
•
|
x
|
•
|
||
| -4 ...2 |
-2 ...4
|
0.1
|
0.1
|
x
|
•
|
x
|
x
|
x
|
•
|
•
|
•
|
•
|
||
| -6 ...4 |
-4 ...6
|
0.2
|
0.2
|
x
|
•
|
•
|
x
|
x
|
•
|
•
|
•
|
•
|
||
| -10 ...6 |
-6 ...10
|
0.5
|
0.5
|
x
|
•
|
•
|
x
|
x
|
•
|
•
|
•
|
•
|
||
| -15 ...10 |
-10 ...15
|
0.5
|
0.5
|
•
|
•
|
•
|
x
|
•
|
•
|
•
|
•
|
•
|
||
| -25 ...15 |
-15 ...25
|
1
|
1
|
•
|
•
|
•
|
•
|
•
|
•
|
•
|
•
|
•
|
||
| -40 ...20 |
-20 ...40
|
1
|
1
|
•
|
•
|
•
|
•
|
•
|
•
|
•
|
•
|
•
|
||
| -60 ...40 |
-40 ...60
|
2
|
2
|
•
|
•
|
•
|
•
|
•
|
•
|
•
|
•
|
•
|
||
| -100 ...60 |
-60 ...100
|
5
|
5
|
•
|
•
|
•
|
•
|
•
|
•
|
•
|
•
|
•
|
||
| -150 ...100 |
-100 ...150
|
5
|
5
|
•
|
•
|
•
|
•
|
•
|
•
|
•
|
•
|
•
|
||
| -250 ...150 |
-150 ...250
|
10
|
10
|
•
|
•
|
•
|
•
|
•
|
•
|
•
|
•
|
•
|
||
| 0 ...4000
upto 0 ...7000 see page 4a |
||||||||||||||
| NON STANDARD RANGES | ||||||||||||||
|
e.g. 0-50 bar
|
||||||||||||||
|
DOUBLE SCALES
|
||||||||||||||
|
e.g. mbar/mmWc, mbar/Pa, etc.
|
q
|
|||||||||||||
|
ACCURACY
|
||||||||||||||
|
±1.6% F.S. (class 1.6)
|
•
|
•
|
•
|
•
|
•
|
•
|
•
|
•
|
•
|
|||||
|
±1.0% F.S. (class 1.0)*
|
q
|
q
|
q
|
x
|
q
|
q
|
q
|
q
|
q
|
|||||
|
Mirrorscale
|
x
|
q
|
q
|
x
|
x
|
x
|
x
|
x
|
x
|
|||||
|
|
||||||||||||||
|
x
|
NOT AVAILABLE
|
*
|
not for type PMS and PMX
|
|||||||||||
|
•
|
STANDARD
|
**
|
Scale in psi,kPa, kg/cm²,
mWC etc. available with no extra charge
|
|||||||||||
|
MARKING FOR
PRESSURE GAUGES
|
|
| OPTIONS | EXTRA PRICE |
| TAG number on dial | |
| TAG number on AISI304/1.4301 TAG plate 55x25 mm | |
| Lettering on dial | |
| Red mark on dial | |
|
CERTIFICATES FOR
PRESSURE GAUGES
|
|||
| TYPE OF CERTIFICATE | EXTRA PRICE | ||
| Certificate of Conformity acc. to EN 10204 2.2. | |||
| Material certificate wetted parts acc. to EN 10204 3.1.B | |||
| Calibration certificate pressure gauge (Traceable to N.K.O.) |
<=2500
|
2500
-4000 |
>=4000
|
| Red mark on dial | |||
| Calibration certificate pressure gauge with transmitter (see page 27) (Traceable to N.K.O.) |
N.A.
|
N.A.
|
|
| Calibration certificates for type PBB (duplex) (Traceable to N.K.O.) |
N.A.
|
N.A.
|
|