DIAPHRAGM TYPE PRESSURE GAUGE, TYPE PMX
TYPE PMX, all stainless steel with diaphragm
STANDARD MODEL
case bayonet lock, AISI304/1.4301, IP-45 ranges diaphragm Ø160 mm: 25 upto 400 mbar, acc. to EN 837-3
diaphragm Ø100 mm: 0,6 upto 25 bar, acc. to EN 837-3
vacuum, compound and pressure, (see page 22-23)
wetted parts diaphragm AISI316Ti/1.4571  
window mineral glass 4mm  
dial aluminium, black figures on white accurarcy case Ø100 and Ø160 : ± 1.6% F.S./class 1.6
pointer aluminium, black application general and heavy industry
movement nickel plated brass with external adjustment device options see page 24-25, electrical contact only possible with case Ø160 mm: type I-Intervall: see page 27
       
TYPE
MODEL
CONNECTION
PRESSURE

CASE DIAMETER xxx (Ø in mm)

MIN
MAX
100
160
PMX100XE-02
-
½"BSP or ½"NPT,
AISI316/1.4401
0.6 bar
25 bar
...
...
PMX160XE-02
-
½"BSP or ½"NPT,
AISI316/1.4401
25 mbar
400 mbar
...
...
PMX100XG-02
-
½"BSP or ½"NPT,
AISI316/1.4401
0.6 bar
25 bar
...
...
PMX160XG-02
-
½"BSP or ½"NPT,
AISI316/1.4401
25 mbar
400 mbar
...
...
PMX100XE-05
-
DIN-NW25 PN40
AISI316/1.4401
0.6 bar
25 bar
...
...
PMX100XE-06
DIN-NW25 PN40
PTFE LINING
PMX160XE-08
-
DIN-NW50 PN40
AISI316/1.4401
25 mbar
400 mbar
...
...
PMX160XE-09
DIN-NW50 PN40
PTFE LINING
40 mbar
400 mbar
...
...
OPTIONS
min
max
EXTRA COSTS
ELECTRICAL
DEVICE
"Hz"CONTACT ONLY for case Ø 160 mm: type I-Intervall
see page 27
OVERRANGE
PROTECTION
UPTO 5 TIMES FULL SCALE (MAX. 40 bar)
25 mbar 25 bar
...
...
PT5 Transmitter and 2 contacts
ONLY for case Ø100 mm: see page 50
NOTE:
LIQUID FILLING NOT POSSIBLE